Select an Error Code or Type an Error Code to begin searching
Error
Xerox WorkCentre 5875 Top Searches
These results are ranked by popularity.
Error
311-005-00-120, 311-006-00-120
Description: Front Tamper Move Failure RAP 311-005-00-120 Front tamper fails to move to the front position. 311-006-00-120 Front tamper fails to move to the rear position.
311-130-00-171, 311-132-00-171
Description: HVF Top Exit Sensor RAP 311-130-00-171 The paper leading edge is late arriving at the top exit sensor. 311-132-00-171 The paper trailing edge is late leaving the top exit sensor.
374-100-00
Description: Tray 4 Elevator Lift Failure RAP 374-100-00 Tray 4 stack height sensor did not actuate within the correct time after the elevator motor turned on. NOTE: Rapid closure of tray 3 when tray 4 is being elevated may cause this fault.
391-060-00
Description: HVPS Fault RAP 391-060-00 The HVPS fault sensor has detected a high voltage fault. The HVPS fault will occur when: • The (C) charge high voltage supply has a short or open circuit. • The (G) charge grid high voltage supply has a short or ope
311J-120
Description: 1K LCSS Poor Stacking RAP Use this RAP to find the cause of poor stacking in the 1K LCSS.
Xerox WorkCentre 5875 Common Errors
The most common error codes.
Error
311-005-00-120, 311-006-00-120
Description: Front Tamper Move Failure RAP 311-005-00-120 Front tamper fails to move to the front position. 311-006-00-120 Front tamper fails to move to the rear position.
311-130-00-171, 311-132-00-171
Description: HVF Top Exit Sensor RAP 311-130-00-171 The paper leading edge is late arriving at the top exit sensor. 311-132-00-171 The paper trailing edge is late leaving the top exit sensor.
374-100-00
Description: Tray 4 Elevator Lift Failure RAP 374-100-00 Tray 4 stack height sensor did not actuate within the correct time after the elevator motor turned on. NOTE: Rapid closure of tray 3 when tray 4 is being elevated may cause this fault.
391-060-00
Description: HVPS Fault RAP 391-060-00 The HVPS fault sensor has detected a high voltage fault. The HVPS fault will occur when: • The (C) charge high voltage supply has a short or open circuit. • The (G) charge grid high voltage supply has a short or ope
311J-120
Description: 1K LCSS Poor Stacking RAP Use this RAP to find the cause of poor stacking in the 1K LCSS.
374-100-00
Description: Tray 4 Elevator Lift Failure RAP 374-100-00 Tray 4 stack height sensor did not actuate within the correct time after the elevator motor turned on. NOTE: Rapid closure of tray 3 when tray 4 is being elevated may cause this fault.
391-060-00
Description: HVPS Fault RAP 391-060-00 The HVPS fault sensor has detected a high voltage fault. The HVPS fault will occur when: • The (C) charge high voltage supply has a short or open circuit. • The (G) charge grid high voltage supply has a short or ope
311-005-00-120, 311-006-00-120
Description: Front Tamper Move Failure RAP 311-005-00-120 Front tamper fails to move to the front position. 311-006-00-120 Front tamper fails to move to the rear position.
311J-120
Description: 1K LCSS Poor Stacking RAP Use this RAP to find the cause of poor stacking in the 1K LCSS.
311-130-00-171, 311-132-00-171
Description: HVF Top Exit Sensor RAP 311-130-00-171 The paper leading edge is late arriving at the top exit sensor. 311-132-00-171 The paper trailing edge is late leaving the top exit sensor.