L6 10 | Description: Polygon motor lock detected. It was judged that there is no output of polygon motor lock signal of LSU. The lock signal was checked at about 10-second intervals after the polygon motor started rotating. As result, it was judged that the poly |
F1 00 | Description: Sorter communication trouble. Communication line test error occurs when power is turned on or after the exit of a simulation mode. Improper communication with sorter |
U5 12 | Description: RADF transport motor driving error |
F3 22 | Description: Lower cassette lift-up trouble. LPED does not turn on within the specified time. LLUD does not turn on within the specified time. |
C1 00 | Description: MC trouble. Main charger output error (output released) Trouble signal from high-voltage transformer |
The most common error codes.
Error | |
---|---|
L6 10 | Description: Polygon motor lock detected. It was judged that there is no output of polygon motor lock signal of LSU. The lock signal was checked at about 10-second intervals after the polygon motor started rotating. As result, it was judged that the poly |
F1 00 | Description: Sorter communication trouble. Communication line test error occurs when power is turned on or after the exit of a simulation mode. Improper communication with sorter |
U5 12 | Description: RADF transport motor driving error |
F3 22 | Description: Lower cassette lift-up trouble. LPED does not turn on within the specified time. LLUD does not turn on within the specified time. |
C1 00 | Description: MC trouble. Main charger output error (output released) Trouble signal from high-voltage transformer |
L6 10 | Description: Polygon motor lock detected. It was judged that there is no output of polygon motor lock signal of LSU. The lock signal was checked at about 10-second intervals after the polygon motor started rotating. As result, it was judged that the poly |
F1 00 | Description: Sorter communication trouble. Communication line test error occurs when power is turned on or after the exit of a simulation mode. Improper communication with sorter |
U5 12 | Description: RADF transport motor driving error |
F3 22 | Description: Lower cassette lift-up trouble. LPED does not turn on within the specified time. LLUD does not turn on within the specified time. |
C1 00 | Description: MC trouble. Main charger output error (output released) Trouble signal from high-voltage transformer |