These results are ranked by popularity.
Error | |
---|---|
C4000 | Description: Polygon motor synchronization problem • The polygon motor does not reach the stable speed within 15 s of the START signal turning on. |
C0150 | Description: Backup memory read/write problem (engine board (KP-5238)) • Read and write data does not match. |
C4010 | Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 5 s after the polygon motor rotation has been stabilized. |
C0160 | Description: Backup memory data problem (engine board (KP-5238)) • Data in the specified area of the backup memory does not match the specified values. |
C6000 | Description: Broken fixing heater wire • In fixing warm-up, the time to reach 50°C/122 °F exceeds 13.5 s, the time to reach 100°C/212 °F exceeds 10 s, the time to reach the primary stabilization exceeds 10 s or the time to reach the secondary stabilizati |
The most common error codes.
Error | |
---|---|
C4000 | Description: Polygon motor synchronization problem • The polygon motor does not reach the stable speed within 15 s of the START signal turning on. |
C0150 | Description: Backup memory read/write problem (engine board (KP-5238)) • Read and write data does not match. |
C4010 | Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 5 s after the polygon motor rotation has been stabilized. |
C0160 | Description: Backup memory data problem (engine board (KP-5238)) • Data in the specified area of the backup memory does not match the specified values. |
C6000 | Description: Broken fixing heater wire • In fixing warm-up, the time to reach 50°C/122 °F exceeds 13.5 s, the time to reach 100°C/212 °F exceeds 10 s, the time to reach the primary stabilization exceeds 10 s or the time to reach the secondary stabilizati |
C4000 | Description: Polygon motor synchronization problem • The polygon motor does not reach the stable speed within 15 s of the START signal turning on. |
C0150 | Description: Backup memory read/write problem (engine board (KP-5238)) • Read and write data does not match. |
C4010 | Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 5 s after the polygon motor rotation has been stabilized. |
C0160 | Description: Backup memory data problem (engine board (KP-5238)) • Data in the specified area of the backup memory does not match the specified values. |
C6000 | Description: Broken fixing heater wire • In fixing warm-up, the time to reach 50°C/122 °F exceeds 13.5 s, the time to reach 100°C/212 °F exceeds 10 s, the time to reach the primary stabilization exceeds 10 s or the time to reach the secondary stabilizati |