Error |
---|
These results are ranked by popularity.
Error | |
---|---|
C1195 | Description: Paper discharge control motor’s malfunction
|
C6752 | Description: ASIC clock input error (front side) When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected. |
C2A13 | Description: Drum unit/Y new release failure The status with the new unit is not cleared after the new drum unit is set. |
C0211 | Description: Manual feed up/down abnormality • Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate |
C4101 | Description: Polygon motor rotation trouble • The polygon motor fails to turn stably even after the lapse of a given period of time after activating and changing rotation speed the polygon motor. • Motor lock signal detects HIGH for a given period time |
The most common error codes.
Error | |
---|---|
C1195 | Description: Paper discharge control motor’s malfunction
|
C6752 | Description: ASIC clock input error (front side) When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected. |
C2A13 | Description: Drum unit/Y new release failure The status with the new unit is not cleared after the new drum unit is set. |
C0211 | Description: Manual feed up/down abnormality • Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate |
C4101 | Description: Polygon motor rotation trouble • The polygon motor fails to turn stably even after the lapse of a given period of time after activating and changing rotation speed the polygon motor. • Motor lock signal detects HIGH for a given period time |
C6752 | Description: ASIC clock input error (front side) When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected. |
C1195 | Description: Paper discharge control motor’s malfunction
|
C2A13 | Description: Drum unit/Y new release failure The status with the new unit is not cleared after the new drum unit is set. |
C0211 | Description: Manual feed up/down abnormality • Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate |
C9401 | Description: Exposure LED lighting failure The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. |