Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta Bizhub C3320i Top Searches

These results are ranked by popularity.

Error
99-06Description: Controller JAM (print control on the main body is not completed) 99-06 Print control is not completed even after a job has been completed.
C5610Description: PH LD drive communication error. • LD drive write data and read data disagree with each other a predetermined number of consecutive times. • Different PH unit is installed.
C7613Description: Power line A19 error. The fuse detection unit detected an error for a predetermined time.
CD012Description: Mount error due to storage being unformatted • The storage is not logically formatted after the whole data in the storage has been deleted by overwriting. • The storage that has replaced an old one is not logically formatted.
CED01Description: The authentication application information does not exist in the storage in the enhanced server authentication state. With “Enhanced Server Authentication” set, no authentication application registration information is found in the storage.

Konica-Minolta Bizhub C3320i Common Errors

The most common error codes.

Error
99-06Description: Controller JAM (print control on the main body is not completed) 99-06 Print control is not completed even after a job has been completed.
C5610Description: PH LD drive communication error. • LD drive write data and read data disagree with each other a predetermined number of consecutive times. • Different PH unit is installed.
C7613Description: Power line A19 error. The fuse detection unit detected an error for a predetermined time.
CD012Description: Mount error due to storage being unformatted • The storage is not logically formatted after the whole data in the storage has been deleted by overwriting. • The storage that has replaced an old one is not logically formatted.
CED01Description: The authentication application information does not exist in the storage in the enhanced server authentication state. With “Enhanced Server Authentication” set, no authentication application registration information is found in the storage.
P-6 ... P-9Description: Imaging unit (C) failure, Imaging unit (M) failure, Imaging unit (Y) failure, Imaging unit (K) failure All density readings taken from the density pattern produced on the transfer belt are 1.0 g/m2 (IDC sensor photo receiver output) or less
99-06Description: Controller JAM (print control on the main body is not completed) 99-06 Print control is not completed even after a job has been completed.
C5610Description: PH LD drive communication error. • LD drive write data and read data disagree with each other a predetermined number of consecutive times. • Different PH unit is installed.
C7613Description: Power line A19 error. The fuse detection unit detected an error for a predetermined time.
CD012Description: Mount error due to storage being unformatted • The storage is not logically formatted after the whole data in the storage has been deleted by overwriting. • The storage that has replaced an old one is not logically formatted.