Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta Bizhub 308e Top Searches

These results are ranked by popularity.

Error
C0202Description: Tray 1 feeder up/down abnormality. The tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
C40A4, C40C3, C40C5Description: bizhub 368e/308e • C40A1: Mechanical controller sub-CPU communication error • C40A2: Mechanical controller PF communication data error • C40A3: Mechanical controller PF transmission timeout • C40A4: Mechanical controller PF communication pul
C3102Description: bizhub 658e/558e Heating roller failure to turn (bizhub 658e/558e). The hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
16-01, 16-40Description: bizhub 368e/308eMisfeed at transfer LCT feed/transport section. 16-01 The leading edge of the paper is not turned ON the vertical transport sensor (PS133) even after the lapse of a given period of time after the transfer LCT starts to feed p
C1127Description: bizhub 658e/558e/458e Punch oscillating motor drive malfunction. The PK punch oscillating home sensor (PS303) is not turned ON (blocked) or OFF (unblocked) even after the set period of tim

Konica-Minolta Bizhub 308e Common Errors

The most common error codes.

Error
C0202Description: Tray 1 feeder up/down abnormality. The tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
C40A4, C40C3, C40C5Description: bizhub 368e/308e • C40A1: Mechanical controller sub-CPU communication error • C40A2: Mechanical controller PF communication data error • C40A3: Mechanical controller PF transmission timeout • C40A4: Mechanical controller PF communication pul
C3102Description: bizhub 658e/558e Heating roller failure to turn (bizhub 658e/558e). The hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
16-01, 16-40Description: bizhub 368e/308eMisfeed at transfer LCT feed/transport section. 16-01 The leading edge of the paper is not turned ON the vertical transport sensor (PS133) even after the lapse of a given period of time after the transfer LCT starts to feed p
C1127Description: bizhub 658e/558e/458e Punch oscillating motor drive malfunction. The PK punch oscillating home sensor (PS303) is not turned ON (blocked) or OFF (unblocked) even after the set period of tim
C5601Description: bizhub 368e/308e Engine control malfunction. Engine control malfunction is detected with port monitor control.
C3102Description: bizhub 658e/558e Heating roller failure to turn (bizhub 658e/558e). The hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
C40A4, C40C3, C40C5Description: bizhub 368e/308e • C40A1: Mechanical controller sub-CPU communication error • C40A2: Mechanical controller PF communication data error • C40A3: Mechanical controller PF transmission timeout • C40A4: Mechanical controller PF communication pul
C2557Description: bizhub 368e/308e Abnormally low toner density detected black TCR sensor. When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row ev
16-01, 16-40Description: bizhub 368e/308eMisfeed at transfer LCT feed/transport section. 16-01 The leading edge of the paper is not turned ON the vertical transport sensor (PS133) even after the lapse of a given period of time after the transfer LCT starts to feed p