Error
C-2304Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal
C-C105Description: ISW write abnormality 2 of the printer control board.
C-1263Description: It does not stop even after a specified period of time after the trimmer blade motor (M31) starts the operation.
C-2102Description: Charger cleaning motor (M23) power abnormality.
C-6710Description: Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally.

Konica-Minolta bizhub PRESS 1250p Common Errors

The most common error codes.

Error
C-2304Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal
C-C105Description: ISW write abnormality 2 of the printer control board.
C-1263Description: It does not stop even after a specified period of time after the trimmer blade motor (M31) starts the operation.
C-2102Description: Charger cleaning motor (M23) power abnormality.
C-6710Description: Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally.
C-0387Description: PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) power abnormality. The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blow
C-6710Description: Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally.
C-5313Description: Suction cooling fan /1 (FM6) rotation abnormality 1. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is not det
C-1136Description: After the punch switchover motor (M608) turns ON, punch switchover switch (MS601) does not turn ON from OFF, or not turn OFF from ON within a specified period of time.
C-0615Description: 2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of