Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta bizhub PRESS 1250 Top Searches

These results are ranked by popularity.

Error
C-2102Description: Charger cleaning motor (M23) power abnormality.
C-C105Description: ISW write abnormality 2 of the printer control board.
C-0615Description: 2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of
C-6710Description: Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally.
C-2304Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal

Konica-Minolta bizhub PRESS 1250 Common Errors

The most common error codes.

Error
C-2102Description: Charger cleaning motor (M23) power abnormality.
C-C105Description: ISW write abnormality 2 of the printer control board.
C-0615Description: 2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of
C-6710Description: Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally.
C-2304Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal
C-0675Description: PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C.
C-2102Description: Charger cleaning motor (M23) power abnormality.
C-2304Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal
C-1451Description: When the FD is unready, a signal to start operations is received from the main body.
C-1320Description: An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan /Rr (FM5) is ON.