Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta bizhub Pro 1200P Top Searches

These results are ranked by popularity.

Error
C-0421Description: Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
C-0532Description: 2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection sign
C-0580Description: PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP)
C-1537Description: Cover paper tray lift motor (M73) drive abnormality. The tray moving up has not been completed within a specified period of time after M73 turns ON. 35-3
C-2206Description: Drum motor (M2) drive abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected with

Konica-Minolta bizhub Pro 1200P Common Errors

The most common error codes.

Error
C-0421Description: Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
C-0532Description: 2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection sign
C-0580Description: PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP)
C-1537Description: Cover paper tray lift motor (M73) drive abnormality. The tray moving up has not been completed within a specified period of time after M73 turns ON. 35-3
C-2206Description: Drum motor (M2) drive abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected with
C-0421Description: Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
C-2206Description: Drum motor (M2) drive abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected with
C-2309Description: Developing cooling fan (FM31) rotation abnormality. The FMx error detection signal is detected twice in succession within a specified period of time after FMx was turned ON. However, error detection signals V cut off/blowout of ICP) are not
C-3502Description: Thermistor /3 (TH3) high temperature abnormality (software). TH3 detects a temperature of 230°C or above 5 times in a period of 1second.
C-0372Description: 2nd tandem PF-702/703 paper feed assist fan /Rr1 (FM2) power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (bl