Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta bizhub Pro 1200P Top Searches

These results are ranked by popularity.

Error
C-0382Description: 2nd tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection si
C-D010Description: Hard disk /1 (HDD1) overwrite erase execution. HDD overwrite erase is executed.
C-3906Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 6
C-0118Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.
C-8410Description: Centering sensor /Fr (PS320) abnormality. 18-4

Konica-Minolta bizhub Pro 1200P Common Errors

The most common error codes.

Error
C-0382Description: 2nd tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection si
C-D010Description: Hard disk /1 (HDD1) overwrite erase execution. HDD overwrite erase is executed.
C-3906Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 6
C-0118Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.
C-8410Description: Centering sensor /Fr (PS320) abnormality. 18-4
C-5312Description: Suction cooling fan /1 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, 24V is normal, but an error detection signal (blowout o
C-0671Description: PI-PFU (PF-703) dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal.
C-1509Description: SC roller release motor (M18) drive abnormality. The SC roller release operation has not been completed within a specified period of time after M18 turns ON. 35-4
C-0323Description: Paper feed assist fan /Fr1 (FM20) rotation abnormality + 24V power abnormality. The FM20EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. At this time, an error detection si
C-0118Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.