Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Konica-Minolta bizhub Pro 1050 Top Searches

These results are ranked by popularity.

Error
SC46-91Description: Header readout address abnormality.
SC53-04Description: The 24V power source for the key counter (CNT2) is checked. When the CNT2 is turned ON from OFF, an error detection signal (blowout of a fuse/24V cut off) is detected.
SC18-52Description: When the upper limit sensor /3 (PS83) is OFF, the PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected.
SC76-03Description: The alignment plate home sensor (PS12) does not turn OFF within a specified period of time after the alignment motor (M7) of the tandem (1st) LS turns ON. Or, the PS12 does not turn ON within a specified period of time.
SC77-31Description: After the 2nd folding release motor (M15) turns ON, the 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time.

Konica-Minolta bizhub Pro 1050 Common Errors

The most common error codes.

Error
SC46-91Description: Header readout address abnormality.
SC53-04Description: The 24V power source for the key counter (CNT2) is checked. When the CNT2 is turned ON from OFF, an error detection signal (blowout of a fuse/24V cut off) is detected.
SC18-52Description: When the upper limit sensor /3 (PS83) is OFF, the PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected.
SC76-03Description: The alignment plate home sensor (PS12) does not turn OFF within a specified period of time after the alignment motor (M7) of the tandem (1st) LS turns ON. Or, the PS12 does not turn ON within a specified period of time.
SC77-31Description: After the 2nd folding release motor (M15) turns ON, the 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time.
SC46-01Description: APC abnormality. While in the image write, the APC is not applicable for the correction of the sub scan beam. Due to the 12V DC power for the laser drive not supplied, the MPC being wrong and the laser defective, the laser does not light up.
SC46-91Description: Header readout address abnormality.
SC18-52Description: When the upper limit sensor /3 (PS83) is OFF, the PS83 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for lifting operation. And at this time, an error detection signal (blowout of a fuse) is detected.
SC53-04Description: The 24V power source for the key counter (CNT2) is checked. When the CNT2 is turned ON from OFF, an error detection signal (blowout of a fuse/24V cut off) is detected.
SC76-03Description: The alignment plate home sensor (PS12) does not turn OFF within a specified period of time after the alignment motor (M7) of the tandem (1st) LS turns ON. Or, the PS12 does not turn ON within a specified period of time.