These results are ranked by popularity.
Error | |
---|---|
1610 | Description: Roll/Reel Units mismatch error The combination of the Roll Unit and Reel Unit may be wrong; one of the units may be an optional unit. |
142E | Description: Circulation pump motor velocity deviation error When the circulation pump motor should speed up or slow down, it was driving at an abnormally high speed exceeding a predetermined velocity.• Overload• Failure of the circulation pump motor enc |
1A39 | Description: Head error • Connection failure of the Head FFC.• Electric parts or components are damaged due to improper Head FFC connection such as connecting it at an angle.• The drive circuit in the Print Head is damaged.• The fuse of the Main Board ha |
1229 | Description: PF Motor oscillation error The control terminal (Vre terminal) of the PF Motor driver has shorted out. |
Dxxy | Description: Service call for FW debugging This error is intended to be used in the product development stage. It is supposed to not occur with marketed product, but may occur due to an unexpected cause such as external noises. |
The most common error codes.
Error | |
---|---|
1610 | Description: Roll/Reel Units mismatch error The combination of the Roll Unit and Reel Unit may be wrong; one of the units may be an optional unit. |
142E | Description: Circulation pump motor velocity deviation error When the circulation pump motor should speed up or slow down, it was driving at an abnormally high speed exceeding a predetermined velocity.• Overload• Failure of the circulation pump motor enc |
1A39 | Description: Head error • Connection failure of the Head FFC.• Electric parts or components are damaged due to improper Head FFC connection such as connecting it at an angle.• The drive circuit in the Print Head is damaged.• The fuse of the Main Board ha |
1229 | Description: PF Motor oscillation error The control terminal (Vre terminal) of the PF Motor driver has shorted out. |
Dxxy | Description: Service call for FW debugging This error is intended to be used in the product development stage. It is supposed to not occur with marketed product, but may occur due to an unexpected cause such as external noises. |
1610 | Description: Roll/Reel Units mismatch error The combination of the Roll Unit and Reel Unit may be wrong; one of the units may be an optional unit. |
142E | Description: Circulation pump motor velocity deviation error When the circulation pump motor should speed up or slow down, it was driving at an abnormally high speed exceeding a predetermined velocity.• Overload• Failure of the circulation pump motor enc |
1A39 | Description: Head error • Connection failure of the Head FFC.• Electric parts or components are damaged due to improper Head FFC connection such as connecting it at an angle.• The drive circuit in the Print Head is damaged.• The fuse of the Main Board ha |
1229 | Description: PF Motor oscillation error The control terminal (Vre terminal) of the PF Motor driver has shorted out. |
Dxxy | Description: Service call for FW debugging This error is intended to be used in the product development stage. It is supposed to not occur with marketed product, but may occur due to an unexpected cause such as external noises. |