Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Epson SC-S30650 Top Searches

These results are ranked by popularity.

Error
1931Description: HTC common elements communication error • Connection failure between the Main Board and Sub-E Board such as cable disconnection• There is something wrong with the elements on the Sub-E Board.• There is something wrong with the communication
151Description: APG Motor reversing error The number of occurrences of reversing the APG Motor has reached a predetermined limit.• The polarity of APG Motor cable is opposite.• APG Motor failure
1125Description: CR HP detection error The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position.• CR HP Sensor failure• False detection of the home due to paper jam or any other obstacle• Misreading of the CR Scale•
15A9Description: Reel Motor oscillation error The control terminal (Vre terminal) of the Reel Motor driver has shorted out.
122DDescription: PF Motor driving time-out error Abnormally-long driving duration of the PF Motor was detected.• Irregular load• Firmware becomes out of control.

Epson SC-S30650 Common Errors

The most common error codes.

Error
1931Description: HTC common elements communication error • Connection failure between the Main Board and Sub-E Board such as cable disconnection• There is something wrong with the elements on the Sub-E Board.• There is something wrong with the communication
151Description: APG Motor reversing error The number of occurrences of reversing the APG Motor has reached a predetermined limit.• The polarity of APG Motor cable is opposite.• APG Motor failure
1125Description: CR HP detection error The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position.• CR HP Sensor failure• False detection of the home due to paper jam or any other obstacle• Misreading of the CR Scale•
15A9Description: Reel Motor oscillation error The control terminal (Vre terminal) of the Reel Motor driver has shorted out.
122DDescription: PF Motor driving time-out error Abnormally-long driving duration of the PF Motor was detected.• Irregular load• Firmware becomes out of control.
1931Description: HTC common elements communication error • Connection failure between the Main Board and Sub-E Board such as cable disconnection• There is something wrong with the elements on the Sub-E Board.• There is something wrong with the communication
151Description: APG Motor reversing error The number of occurrences of reversing the APG Motor has reached a predetermined limit.• The polarity of APG Motor cable is opposite.• APG Motor failure
1125Description: CR HP detection error The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position.• CR HP Sensor failure• False detection of the home due to paper jam or any other obstacle• Misreading of the CR Scale•
15A9Description: Reel Motor oscillation error The control terminal (Vre terminal) of the Reel Motor driver has shorted out.
122DDescription: PF Motor driving time-out error Abnormally-long driving duration of the PF Motor was detected.• Irregular load• Firmware becomes out of control.