These results are ranked by popularity.
Error | |
---|---|
E002-0030 | Description: The rise in the temperature of the fixing assembly is not enough. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB or the DC con |
E351-0000 | Description: There is an error in the main controller PCB (sub). At start-up, there is an error in the communication between main controller PCB (sub) and the main controller PCB (main). |
E079-0002 | Description: The home position of the outside heating roller is not detected. The outside heating roller home position sensor does not go off. If there is an open circuit in the home position sensor of the outside heating roller home position sensor, th |
E731 | Description: There is a UFR board error. |
E020-xxD5 | Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INTI control (service mode INISET-*) at time of initial setup, the average of the light Ref values is 562 or higher. The ATR sensor is dam |
The most common error codes.
Error | |
---|---|
E002-0030 | Description: The rise in the temperature of the fixing assembly is not enough. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB or the DC con |
E351-0000 | Description: There is an error in the main controller PCB (sub). At start-up, there is an error in the communication between main controller PCB (sub) and the main controller PCB (main). |
E079-0002 | Description: The home position of the outside heating roller is not detected. The outside heating roller home position sensor does not go off. If there is an open circuit in the home position sensor of the outside heating roller home position sensor, th |
E731 | Description: There is a UFR board error. |
E020-xxD5 | Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INTI control (service mode INISET-*) at time of initial setup, the average of the light Ref values is 562 or higher. The ATR sensor is dam |
E002-0030 | Description: The rise in the temperature of the fixing assembly is not enough. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB or the DC con |
E351-0000 | Description: There is an error in the main controller PCB (sub). At start-up, there is an error in the communication between main controller PCB (sub) and the main controller PCB (main). |
E079-0002 | Description: The home position of the outside heating roller is not detected. The outside heating roller home position sensor does not go off. If there is an open circuit in the home position sensor of the outside heating roller home position sensor, th |
E731 | Description: There is a UFR board error. |
E020-xxD5 | Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INTI control (service mode INISET-*) at time of initial setup, the average of the light Ref values is 562 or higher. The ATR sensor is dam |