Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Canon iRC6800 Top Searches

These results are ranked by popularity.

Error
E020-xx13Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INIT control (service mode INISET-*) at time of initial setup, the Ref value is 960 or higher. The ATR sensor is damaged or has an open ci
E003-0051Description: After standby, the drop in the temperature of the fixing assembly is excessive. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB
E719-0002Description: error in communication with coin vendor/card reader - The IPC cable to the coin vendor is broken and the IPC communication cannot be recovered. - There is an open circuit in the pickup delivery signal line. - An improper connection is detec
E240-0000Description: There is a DDI-P communication error. There is a DDI-P communication error (error in communication between master and slave 0).
E032-0001Description: The NE connector counter does not operate. There is an open circuit in the line for the count pulse signal.

Canon iRC6800 Common Errors

The most common error codes.

Error
E020-xx13Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INIT control (service mode INISET-*) at time of initial setup, the Ref value is 960 or higher. The ATR sensor is damaged or has an open ci
E003-0051Description: After standby, the drop in the temperature of the fixing assembly is excessive. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB
E719-0002Description: error in communication with coin vendor/card reader - The IPC cable to the coin vendor is broken and the IPC communication cannot be recovered. - There is an open circuit in the pickup delivery signal line. - An improper connection is detec
E240-0000Description: There is a DDI-P communication error. There is a DDI-P communication error (error in communication between master and slave 0).
E032-0001Description: The NE connector counter does not operate. There is an open circuit in the line for the count pulse signal.
E020-xx13Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction For INIT control (service mode INISET-*) at time of initial setup, the Ref value is 960 or higher. The ATR sensor is damaged or has an open ci
E003-0051Description: After standby, the drop in the temperature of the fixing assembly is excessive. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB
E719-0002Description: error in communication with coin vendor/card reader - The IPC cable to the coin vendor is broken and the IPC communication cannot be recovered. - There is an open circuit in the pickup delivery signal line. - An improper connection is detec
E240-0000Description: There is a DDI-P communication error. There is a DDI-P communication error (error in communication between master and slave 0).
E032-0001Description: The NE connector counter does not operate. There is an open circuit in the line for the count pulse signal.