Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Canon iR3245F Top Searches

These results are ranked by popularity.

Error
E064-0003Description: The voltage of the power supply is faulty (high-voltage error). While output is being generated, the AD value of the developing DC voltage is 224 (DEC) or more for 10 msec 2 times in sequence. (However, after output, it is not detected for
E5F9-0003Description: Saddle switch error The delivery cover switch has been identified as being open after the start of printing or the start of initial rotation of the host machine with the following sensors identifying their respective covers as being closed:
E591-0001Description: Punch dust sensor error Error in light-receiving voltage while light is emitted
E804-0000Description: Error in power supply cooling fan Failure in power supply cooling fan (while the fan is not working) When lock signal is detected for 5 sec while the fan is stopped.
E315-0510Description: There is an error in image data. Device: timeout error [Location to be detected] image process module (SCIP) [Detection timing] when there is no interruption 2 min after the operation has been started.

Canon iR3245F Common Errors

The most common error codes.

Error
E064-0003Description: The voltage of the power supply is faulty (high-voltage error). While output is being generated, the AD value of the developing DC voltage is 224 (DEC) or more for 10 msec 2 times in sequence. (However, after output, it is not detected for
E5F9-0003Description: Saddle switch error The delivery cover switch has been identified as being open after the start of printing or the start of initial rotation of the host machine with the following sensors identifying their respective covers as being closed:
E591-0001Description: Punch dust sensor error Error in light-receiving voltage while light is emitted
E804-0000Description: Error in power supply cooling fan Failure in power supply cooling fan (while the fan is not working) When lock signal is detected for 5 sec while the fan is stopped.
E315-0510Description: There is an error in image data. Device: timeout error [Location to be detected] image process module (SCIP) [Detection timing] when there is no interruption 2 min after the operation has been started.
E315-0510Description: There is an error in image data. Device: timeout error [Location to be detected] image process module (SCIP) [Detection timing] when there is no interruption 2 min after the operation has been started.
E530-0002Description: Front alignment error (External finisher) The home position sensor does not go on even when the front alignment motor has been rotated for a specific period of time.
E064-0003Description: The voltage of the power supply is faulty (high-voltage error). While output is being generated, the AD value of the developing DC voltage is 224 (DEC) or more for 10 msec 2 times in sequence. (However, after output, it is not detected for
E804-0000Description: Error in power supply cooling fan Failure in power supply cooling fan (while the fan is not working) When lock signal is detected for 5 sec while the fan is stopped.
E591-0001Description: Punch dust sensor error Error in light-receiving voltage while light is emitted