These results are ranked by popularity.
Error | |
---|---|
E010-0001 | Description: Main Motor (M2) rotation error Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds. |
E822-0002 | Description: Delivery Cooling Fan (Center) (FM2) error A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven. *The same status was detected again after executing an error retry. |
E354-0001 | Description: System error |
E540-8001 | Description: Stack Tray Shift Motor (M8) error The Stack Tray Shift Motor (M8) was driven for 4 seconds, but the Stack Tray shifting operation could not be completed. |
E025-0001 | Description: Bottle Motor (M5) error The lock detection flag of the Bottle Motor (M5) was monitored at intervals of 2 msec, and the same level was detected 800 times in a row. * If paper is being fed, the error occurs after the paper has been delivered. |
The most common error codes.
Error | |
---|---|
E010-0001 | Description: Main Motor (M2) rotation error Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds. |
E822-0002 | Description: Delivery Cooling Fan (Center) (FM2) error A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven. *The same status was detected again after executing an error retry. |
E354-0001 | Description: System error |
E540-8001 | Description: Stack Tray Shift Motor (M8) error The Stack Tray Shift Motor (M8) was driven for 4 seconds, but the Stack Tray shifting operation could not be completed. |
E025-0001 | Description: Bottle Motor (M5) error The lock detection flag of the Bottle Motor (M5) was monitored at intervals of 2 msec, and the same level was detected 800 times in a row. * If paper is being fed, the error occurs after the paper has been delivered. |
E010-0001 | Description: Main Motor (M2) rotation error Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds. |
E822-0002 | Description: Delivery Cooling Fan (Center) (FM2) error A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven. *The same status was detected again after executing an error retry. |
E354-0001 | Description: System error |
E540-8001 | Description: Stack Tray Shift Motor (M8) error The Stack Tray Shift Motor (M8) was driven for 4 seconds, but the Stack Tray shifting operation could not be completed. |
E025-0001 | Description: Bottle Motor (M5) error The lock detection flag of the Bottle Motor (M5) was monitored at intervals of 2 msec, and the same level was detected 800 times in a row. * If paper is being fed, the error occurs after the paper has been delivered. |