These results are ranked by popularity.
Error | |
---|---|
E001-0001 | Description: Abnormally high temperature (detected by sub thermistor) - The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control. |
E716-0000 | Description: Erroneous communication with optional cassette - Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication. |
0010 | Description: Pickup NG SR2003 - The registration sensor has been held off since paper pickup started. |
E002-0000 | Description: Low temperature during temperature control. - The target temperature is not reached during temperature control. |
E719-0000 | Description: Erroneous communication with card reader (serial communication) - Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on). - A serial comm |
The most common error codes.
Error | |
---|---|
E001-0001 | Description: Abnormally high temperature (detected by sub thermistor) - The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control. |
E716-0000 | Description: Erroneous communication with optional cassette - Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication. |
0010 | Description: Pickup NG SR2003 - The registration sensor has been held off since paper pickup started. |
E002-0000 | Description: Low temperature during temperature control. - The target temperature is not reached during temperature control. |
E719-0000 | Description: Erroneous communication with card reader (serial communication) - Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on). - A serial comm |
E001-0001 | Description: Abnormally high temperature (detected by sub thermistor) - The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control. |
E716-0000 | Description: Erroneous communication with optional cassette - Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication. |
0010 | Description: Pickup NG SR2003 - The registration sensor has been held off since paper pickup started. |
E002-0000 | Description: Low temperature during temperature control. - The target temperature is not reached during temperature control. |
E719-0000 | Description: Erroneous communication with card reader (serial communication) - Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on). - A serial comm |