Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Sharp AR5520S Top Searches

These results are ranked by popularity.

Error
H3 00Description: Heat roller high temperature detection. The fusing temperature exceeds 240C°.
U2 12Description: Adjustment value check sum error (EEPROM). Check sum error of the adjustment value area in the EEPROM
E7 02Description: LSU trouble. The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
H4 00Description: Heat roller low temperature detection. When the fusing temperature is 150C° or less in 55 sec from starting warming-up. When the warm-up complete temperature is not reached in 30 sec from reaching 150C°. When the fusing temperature is less t
U2 40Description: CRUM chip communication error. An error occurs during communication between the MCU and the CRUM chip. The CRUM identification error occurs.

Sharp AR5520S Common Errors

The most common error codes.

Error
H3 00Description: Heat roller high temperature detection. The fusing temperature exceeds 240C°.
U2 12Description: Adjustment value check sum error (EEPROM). Check sum error of the adjustment value area in the EEPROM
E7 02Description: LSU trouble. The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
H4 00Description: Heat roller low temperature detection. When the fusing temperature is 150C° or less in 55 sec from starting warming-up. When the warm-up complete temperature is not reached in 30 sec from reaching 150C°. When the fusing temperature is less t
U2 40Description: CRUM chip communication error. An error occurs during communication between the MCU and the CRUM chip. The CRUM identification error occurs.
H3 00Description: Heat roller high temperature detection. The fusing temperature exceeds 240C°.
U2 12Description: Adjustment value check sum error (EEPROM). Check sum error of the adjustment value area in the EEPROM
E7 02Description: LSU trouble. The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
H4 00Description: Heat roller low temperature detection. When the fusing temperature is 150C° or less in 55 sec from starting warming-up. When the warm-up complete temperature is not reached in 30 sec from reaching 150C°. When the fusing temperature is less t
U2 40Description: CRUM chip communication error. An error occurs during communication between the MCU and the CRUM chip. The CRUM identification error occurs.