Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Ricoh MPC7500SP Top Searches

These results are ranked by popularity.

Error
SC455Description: PTR motor error The lock signal from the paper transfer motor was not detected within 1 sec. after the motor switched on.
SC621Description: Mailbox-to-Finisher communication error Communication between the mailbox and finisher is interrupted. An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed.
SC221Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
SC535Description: Development Intake Fan Error The lock signal remained HIGH for 5 sec. while the fan in the Y development unit was operating
SC865Description: HDD access error HDD responded to an error during operation for a condition other than those for SC863, 864.

Ricoh MPC7500SP Common Errors

The most common error codes.

Error
SC455Description: PTR motor error The lock signal from the paper transfer motor was not detected within 1 sec. after the motor switched on.
SC621Description: Mailbox-to-Finisher communication error Communication between the mailbox and finisher is interrupted. An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed.
SC221Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
SC535Description: Development Intake Fan Error The lock signal remained HIGH for 5 sec. while the fan in the Y development unit was operating
SC865Description: HDD access error HDD responded to an error during operation for a condition other than those for SC863, 864.
SC535Description: Development Intake Fan Error The lock signal remained HIGH for 5 sec. while the fan in the Y development unit was operating
SC865Description: HDD access error HDD responded to an error during operation for a condition other than those for SC863, 864.
SC221Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
SC753Description: Stacking Roller Motor Error (B830) The return drive HP sensor did not detect the stacking roller at the HP sensor within 1 sec. -or- The stacking roller did not leave the home position at the specified time.
SC319Description: Drum Charge Error: Y Drum charge output voltage (Vpp) exceeded 2.8 kV.