Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Ricoh MPC4503SP Top Searches

These results are ranked by popularity.

Error
SC921-00Description: Printer application error (Resident font not found) Resident font was not found at printer startup.
SC551-03Description: Edge NC Sensor Short-circuit AD value: 0-13 (FB voltage: 0.000V-0.041V) (*3) is detected for (t14) seconds continuously. Detection period: 100 ms, detection frequency: 10 times or more.
SC361-04Description: TD sensor output error: Upper Limit (Y) TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error threshold (SP3-211-002) continuously exceeded the upper limit occurrence threshold value (SP3-211-003).
SC721-10Description: Transport Motor 1 Error (1K sheet finisher) Motor driver detects an error state (DC motor control error) (1st time is jam notification, 2nd time is SC notification).
SC702-02Description: Protection Device Intercept Error 2 (ARDF) When original source 5V power supply is ON, protection device intercept of 24V OUT power supply system is detected.

Ricoh MPC4503SP Common Errors

The most common error codes.

Error
SC921-00Description: Printer application error (Resident font not found) Resident font was not found at printer startup.
SC551-03Description: Edge NC Sensor Short-circuit AD value: 0-13 (FB voltage: 0.000V-0.041V) (*3) is detected for (t14) seconds continuously. Detection period: 100 ms, detection frequency: 10 times or more.
SC361-04Description: TD sensor output error: Upper Limit (Y) TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error threshold (SP3-211-002) continuously exceeded the upper limit occurrence threshold value (SP3-211-003).
SC721-10Description: Transport Motor 1 Error (1K sheet finisher) Motor driver detects an error state (DC motor control error) (1st time is jam notification, 2nd time is SC notification).
SC702-02Description: Protection Device Intercept Error 2 (ARDF) When original source 5V power supply is ON, protection device intercept of 24V OUT power supply system is detected.
SC551-03Description: Edge NC Sensor Short-circuit AD value: 0-13 (FB voltage: 0.000V-0.041V) (*3) is detected for (t14) seconds continuously. Detection period: 100 ms, detection frequency: 10 times or more.
SC872-00Description: HDD mail reception error An error was detected on the HDD immediately after the machine was turned on.
SC650-01Description: Remote Service Modem Communication Error (Dialup authentication failure) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected
SC361-04Description: TD sensor output error: Upper Limit (Y) TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error threshold (SP3-211-002) continuously exceeded the upper limit occurrence threshold value (SP3-211-003).
SC780-01Description: Bank 2 (Lower optional paper tray) Protection Device Intercept Error When original source of 5V power supply is ON, protection device intercept of 24V power system is detected.