Error
SC530-00Description: Fusing Exhaust Heat Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
SC664-02Description: ASIC on the IOB SRAM program expansion error. Write error to ASIC on the IOB SRAM (write result error)
SC720-20Description: Lower Separation Claw Motor Error (2K/3K sheet finisher)
SC877-00Description: Data Overwrite Security card error The "Auto Erase Memory" function of the Data Overwrite Security is set to on but it cannot be done.
SC230-04Description: FGATE ON error: Ye The FGATE signal did not turn ON within T1 sec. after the writing process of the corresponding color started.

Ricoh MPC3003SP Common Errors

The most common error codes.

Error
SC530-00Description: Fusing Exhaust Heat Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
SC664-02Description: ASIC on the IOB SRAM program expansion error. Write error to ASIC on the IOB SRAM (write result error)
SC720-20Description: Lower Separation Claw Motor Error (2K/3K sheet finisher)
SC877-00Description: Data Overwrite Security card error The "Auto Erase Memory" function of the Data Overwrite Security is set to on but it cannot be done.
SC230-04Description: FGATE ON error: Ye The FGATE signal did not turn ON within T1 sec. after the writing process of the corresponding color started.
SC562-02Description: Pressurized Central Thermistor Does Not Reload Does not reach (T21) degree C after heater 1ON for (t3) seconds.
SC720-20Description: Lower Separation Claw Motor Error (2K/3K sheet finisher)
SC721-42Description: Stapler Displacement Motor Error (1K sheet finisher) • During movement to home, the home position could not be detected within a predetermined pulse (p0 pulse) (1st time is jam notification, 2nd time is SC notification). • During movement fr
SC995-04Description: CPM setting error 4 Comparison of machine serial number (11 digits) and machine identification code.
SC442-00Description: ITB Lift Error Even though the ITB lift motor (also Toner supply motor (M)) rotates, the ITB lift sensor failed to detect the specified sensor feeler status within specified time. • Contact/separation operation: If not detected in 2000msec •