These results are ranked by popularity.
Error | |
---|---|
SC665-04 | Description: IO ASIC Does Not Start The IO ASIC start-up signal is checked every 10 milliseconds. The SC is issued when the IO ASIC start-up signal is not detected although 3 seconds elapsed. |
SC563-00 | Description: Pressurized Central Thermistor High Temperature Detection (software) Above a predetermined temperature detected for specified seconds continuously. Detection period: 100ms, detection count: 10 times or more. |
SC828-00 | Description: Self-diagnostic error: ROM [xxxx]: Detailed error code |
SC720-42 | Description: Edge Stapler Displacement Motor Error (2K/3K sheet finisher) • Motor driver detects an error (short-circuit/ overheating) (1st time, SC). • During movement to home, the home position could not be detected within a predetermined pulse (p0 pul |
SC533-01 | Description: Development Bearing Cooling Fan In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively. |
The most common error codes.
Error | |
---|---|
SC665-04 | Description: IO ASIC Does Not Start The IO ASIC start-up signal is checked every 10 milliseconds. The SC is issued when the IO ASIC start-up signal is not detected although 3 seconds elapsed. |
SC563-00 | Description: Pressurized Central Thermistor High Temperature Detection (software) Above a predetermined temperature detected for specified seconds continuously. Detection period: 100ms, detection count: 10 times or more. |
SC828-00 | Description: Self-diagnostic error: ROM [xxxx]: Detailed error code |
SC720-42 | Description: Edge Stapler Displacement Motor Error (2K/3K sheet finisher) • Motor driver detects an error (short-circuit/ overheating) (1st time, SC). • During movement to home, the home position could not be detected within a predetermined pulse (p0 pul |
SC533-01 | Description: Development Bearing Cooling Fan In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively. |
SC828-00 | Description: Self-diagnostic error: ROM [xxxx]: Detailed error code |
SC720-42 | Description: Edge Stapler Displacement Motor Error (2K/3K sheet finisher) • Motor driver detects an error (short-circuit/ overheating) (1st time, SC). • During movement to home, the home position could not be detected within a predetermined pulse (p0 pul |
SC721-80 | Description: Folding Transport Motor Error (1K sheet finisher) • Motor driver detects an error (short-circuit or overheating) (1st time is SC) |
SC868-02 | Description: SD card access error The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) |
SC563-00 | Description: Pressurized Central Thermistor High Temperature Detection (software) Above a predetermined temperature detected for specified seconds continuously. Detection period: 100ms, detection count: 10 times or more. |