SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.
SC995-01Description: CPM setting error 1 Comparison of machine serial number (11 digits) and machine identification code. Details: • Machine serial number cannot be identified because of BICU replacement or malfunctioning. • Machine serial number cannot be iden
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC722-06Description: Finisher SR3260 Error Access error to NVRAM Error occurs when accessing NV memory.
SC650-13Description: Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation)) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or a

Ricoh IMC2000 Common Errors

The most common error codes.

Error
SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.
SC995-01Description: CPM setting error 1 Comparison of machine serial number (11 digits) and machine identification code. Details: • Machine serial number cannot be identified because of BICU replacement or malfunctioning. • Machine serial number cannot be iden
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC722-06Description: Finisher SR3260 Error Access error to NVRAM Error occurs when accessing NV memory.
SC650-13Description: Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation)) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or a
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC727-01Description: Internal Multi-Fold Unit FD3010 Error Connection Error to Downstream Unit Communication error has occurred with the serial interface of the downstream unit. This is displayed as an SC code from its initial detection.
SC531-01, SC531-03Description: SC531-01 Development Intake Fan/Right Lock SC531-03 Drive Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
SC720-70Description: Booklet Finisher SR3290/Finisher SR3280 Error Folding Transport Motor Error • Motor controller detects an error (overload) (Jam notification for 1st to 4th times, SC notification for 5th time) • During descent, the paper surface sensor still
SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.