Konica-Minolta Bizhub 423 Top Searches

These results are ranked by popularity.

Error
C11A1Description: Tray 2 exit roller pressure/ retraction malfunction • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) i
C5351Description: Power supply cooling fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
S-1Description: CCD gain adjustment failure -It is detected that the CCD clamp gain adjustment value is faulty.
C0214Description: LCT shifting failure • The shifter stop position sensor (PS5B) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop position sensor (PS5B) is not blocked even
C1301Description: Fan motor drive malfunction • While the motor is rotating, the fan lock signal remains L for the set period of time.

Konica-Minolta Bizhub 423 Common Errors

The most common error codes.

Error
C11A1Description: Tray 2 exit roller pressure/ retraction malfunction • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) i
C5351Description: Power supply cooling fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
S-1Description: CCD gain adjustment failure -It is detected that the CCD clamp gain adjustment value is faulty.
C0214Description: LCT shifting failure • The shifter stop position sensor (PS5B) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop position sensor (PS5B) is not blocked even
C1301Description: Fan motor drive malfunction • While the motor is rotating, the fan lock signal remains L for the set period of time.
C11A1Description: Tray 2 exit roller pressure/ retraction malfunction • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) i
S-1Description: CCD gain adjustment failure -It is detected that the CCD clamp gain adjustment value is faulty.
C5351Description: Power supply cooling fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C0214Description: LCT shifting failure • The shifter stop position sensor (PS5B) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop position sensor (PS5B) is not blocked even
C8101Description: Before reading pressure welding alienation mechanism • During a pressure motion being performed, the reading roller release position sensor (PS12) output does not change from H to L. • During a retraction motion being performed, the reading