Select an Error Code or Type an Error Code to begin searching

Error


Have a better picture? Update the product image. PNG Only. Open a new private window or clear your cache to see the new image.


Canon iRC3880 Top Searches

These results are ranked by popularity.

Error
E540-8004Description: Tray up/down error When the input of the clock signal could not be detected within 0.2 sec. during the operation of the 1st tray shift motor
E351-0000Description: Main controller PCB error When a communication error has occurred in the main controller PCB at startup
E020-xx60Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low)
E719-0001Description: Error in communication with coin vendor/card reader When the coin vendor which was connected before the power was turned OFF could not be recognized when the power was turned back ON
E004-0401Description: Fixing unit protection circuit trouble 13 V trouble error

Canon iRC3880 Common Errors

The most common error codes.

Error
E540-8004Description: Tray up/down error When the input of the clock signal could not be detected within 0.2 sec. during the operation of the 1st tray shift motor
E351-0000Description: Main controller PCB error When a communication error has occurred in the main controller PCB at startup
E020-xx60Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low)
E719-0001Description: Error in communication with coin vendor/card reader When the coin vendor which was connected before the power was turned OFF could not be recognized when the power was turned back ON
E004-0401Description: Fixing unit protection circuit trouble 13 V trouble error
E540-8004Description: Tray up/down error When the input of the clock signal could not be detected within 0.2 sec. during the operation of the 1st tray shift motor
E351-0000Description: Main controller PCB error When a communication error has occurred in the main controller PCB at startup
E020-xx60Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low)
E719-0001Description: Error in communication with coin vendor/card reader When the coin vendor which was connected before the power was turned OFF could not be recognized when the power was turned back ON
E004-0401Description: Fixing unit protection circuit trouble 13 V trouble error